BSRIA Instrument Solutions - a comprehensive service for your Test and Measurement requirements
BSRIA Instrument Solutions
Old Bracknell Lane West, Bracknell, Berkshire, RG12 7AH, UK
Tel: +44 (0) 1344 459314 Fax: +44 (0) 1344 465556
Sales : sales@bis.fm Hire : hire@bis.fm Calibration : calibration@bis.fm
Return to home page Contact Us View contents of your Quote
Manufacturers
Airflow Developments
Airflow Instruments
Algodue
Alnor
ASL
Avo Megger
Bruel & Kjaer
BSRIA Instrument Solutions
Budenberg
Calibration
Casella Cel
Castle
CEL
Chauvin Arnoux
Cirrus
Climet
Comark
Comdronic
Compact
Concept
Controlotron
Crane
Crowcon
Dakota
Dent
Digitron
DP Measurement
Draeger
Dranetz
Druck
Elcometer
Elcomponents
Eltek
Extech Instruments
FLIR Systems
Fluke
Furness Controls
GfG
Gigahertz-Optik
Grant
Hawkeye
Henke-Sass Wolf
Ion Science
Isuzu
Jem
Kane May
Katronic
Keller
Kimo
Kolectric
LEM
Macam
Megger
Meterman
Metrix
Metrohm
Micronics
Monitran
NEC
Olympus Industrial
Omega
Particle Measuring Technologies
PMS / Malvern
PMT
Poddymeter
Protimeter
Raytek
Retrotec
Robin
Rotronic
Rustrak
Seaward
Seltek
Shortridge
Sifam Digitron
Sinergy
Sontay
Steptech
Testo
The Energy Conservatory
Time Electronic
TSI
Vaisala
Yokogowa

Chauvin Arnoux


Electrical

Cable Location & Testing
Detec 220
• without dismantling the installation• two modules: 1 transmitter + 1 receiver• the receiver: is connected to a 7 to 250V AC/DC power supply and generates a pulsed voltage without danger to the user• the receiver functions as a homing head • remote. . .
Locat 110 & 220
• accurate location without dismantling the installation• two modules: 1 transmitter + 1 receiver• the transmitter is connected to the circuit to be tested or between a phase and the earth of the circuit without circuit-breaker tripping of the RCD. . .
Clamp Meters
F01
FEATURES• AC intensity: 0. 20 to 40/400A (600A peak)• RMS and DC voltage: 0. 20 to 40/400/600V (900V peak)• Auto AC/DC - Hold• Resistance: 0 to 400Ω/4kΩ /40kΩ• Continuity / buzzer• Range overrun buzzer • Battery charge. . .
F03
Fully automatic, RMS AC & DC, the F03 is a must for all your measurementsFEATURES• clamping: ř26mm• AC and DC intensity: 0. 20 to 40/400A (600A peak)• AC and DC voltage: 0. 20 to 40/400/600V (900V peak)• temperature (int, ext, °C, °F) by K couple. . .
F05
Ideal for U1000RO2V-1X185 2and H07RNF-1x70 cables2 or 20mmx5mm bars, it is a professional measurement tool (600V cat. III). Fully automatic, RMS AC & DC, the F05 is a must for all your measurementsFEATURES• Clamping: Ř26mm• Ac And Dc Intensity:. . .
F07
Ideal for U1000RO2V-1X185 and H07RNF-1x70 cables or 20mmx5mm bars, it is a professional measurement tool (600V cat. III). Fully automatic, TRMS AC & DC, the F07 is a must for all your measurementsFEATURES• Clamping: ř26mm• Ac + dc intensity: 0. 20. . .
F11N
FEATURES• AC intensity: 400 and 700A (2 cal. )• Accuracy 2%±0. 5A on cal. 400A, 2% on cal. 700A• AC & DC voltage: 400 and 600V (2 cal. )• Accuracy 0. 5% for DC, 1% for AC• Bandwidth: 45-450Hz• Average value• Impedance: 1MΩ• Resistance: 400Ω. . .
F13N
FEATURES• AC intensity: 400 and 700A (2 cal. )• Accuracy: 2%±0. 5A• AC & DC voltage: 400 and 600V (2 cal. )• Accuracy: 0. 5%±2ct for DC, over 1%±10ct for AC• Impedance 1MΩ• Bandwidth: 45Hz-450Hz• RMS • Resistance: 400Ω to 4kΩ (2 cal. ),. . .
F15
To ensure impeccable measurement quality, the F15 gives measurements in RMS, whether or not the current is deformed or sinusoidal. In addition, it offers DC measurement with fully automatic zero adjustment. FEATURES• AC (RMS) intensity: 0. 2-400. . .
    F1N
FEATURES• TRMS value of current from 300ma to 400A - 700A and 1000A peak (2 cal. )• Stable or variable frequency from 0. 5Hz to 10khz • 10000-count digital display • HOLD; RANGE• 40-segment analogue bargraph displaying instant value• Battery charge. . .
    F2N
FEATURES• TRMS value of current from 300ma to 400A - 700A and 1000A peak (2 cal. )• Stable or variable frequency from 0. 5Hz to 10khz • 10000-count digital display• Measure of "PEAK" (1ms) current values• Measurement of "SMOOTHED" current and. . .
    F3N
FEATURES• TRMS value of current from 300ma to 400A - 700A and 1000A peak (2 cal. )• Stable or variable frequency from 0. 5Hz to 10khz • 10000-count digital display• Measure of "PEAK" (1ms) current values• Measurement of "SMOOTHED" current and. . .
Disturbance Monitors
CA 8334
The CA8334 combines the functions of a Harmonic, Power Quality & Disturbance analyser (Maximum 50 events) in one easy package. For more information click here.
Earth Testing Equipment
CA 6415
The C. A 6415 is the top-of-the-range model; it has a programmable alarm and measurement memorisation function. FEATURES• Resistance : 0. 10 Ω to 1200 Ω (7 cal. )• RMS leak current: 1ma to 30. 00A (3 cal. )• Alarm function: programming of the. . .
CA6410
FEATURES• Resistance: 0. 10Ω. . . 1200Ω (7 cal. )• Clamping diameter: 32mm• Measuring frequency: 2400Hz• Power supply: 1 x 9V battery for a service life of 1,500 x 30-sec measurements• Battery charge level and remaining battery service life. . .
CA6412
FEATURES• Resistance: 0. 10Ω to 1200Ω• RMS leak current: 1ma to 30,00A• Clamping diameter: 32mm• Measuring frequency: 2400Hz• Power supply: 1 x 9V battery for a service life of 1,500 x 30-sec measurements• Battery charge level and. . .
CA6421
FEATURES• Earth resistance: 0. 5Ωat 1000 Ω (log scale) )• 3 fault presence indicators to validate the measurement• Measurement frequency: 128Hz• Connection of rods to colour-coded terminals • Captive connection strip removable between S. . .
CA6423
FEATURES• Earth resistance: 0. 00 to 2000Ω (3 cal. ) • 3 fault presence indicators to validate the measurement• Measurement frequency: 128Hz• Connection of rods to colour-coded terminals • A captive connection strip, removable between H and S. . .
CA6460
FEATURES• 3 in 1 tester: resistivity, earth, coupling• Measurement range: 0. 00 to 2000w (3 automatic ratings)• Change from 4 wire method to 3 wire method thanks to 1 removable captive bar between e - es • 3 fault presence indicators to validate. . .
CA6462
FEATURES• 3 in 1 tester: resistivity, earth, coupling• measurement range: 0. 00 to 2000Ω (3 automatic ratings)• change from 4 wire method to 3 wire method thanks to 1 removable captive bar between E - ES • 3 fault presence indicators to. . .
Terca 2
FEATURES• 3-in-1 tester: earth, resistivity and coupling• Earth resistance / resistivity: 2ω to 20kω (5 cal. )• 3 measurement currents: 2ma / 10ma / 50ma• Coupling measurement between 2 earths - 4 or 2 wires - by means of 2 captive. . .
Insulation & Continuity testers
CA6511
FEATURES• Insulation: up to 1000MΩ (1cal. ) At 500V DC• AC voltage: 0 to 600V• Continuity: -10Ω to +10Ω (I=200ma)• Automatic testing of absence of voltage by direct measurement• Single input on two colour-coded terminals• Highly. . .
CA6513
FEATURES• Insulation: up to 1000MΩ (1cal. ) At 500V and 1000V DC• AC voltage: 0 to 600V• Resistance: 0 to 1000Ω• Continuity: -10Ω to +10Ω (I=200ma)• Automatic testing of lack of voltage by direct measurement• Single input on two. . .
CA6521
FEATURES• Insulation: up to 2GΩ at 250V and 500V DC• Voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)• Continuity: -20Ω to +20Ω (audible beep)• Giant 400-count display + bargraph (simultaneous. . .
CA6523
FEATURES• Insulation: up to 2GΩ at 500V and 1000V DC• Voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)• Continuity: -20Ω to +20Ω (audible beep and compensation of leads)• Resistance: 0 to. . .
CA6525
FEATURES• Insulation: up to 2GΩ at 250V, 500V and 1000V DC• Voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)• Continuity: -20Ω to +20Ω (audible beep and compensation of leads)• Resistance: 0. . .
CA6531
FEATURES• Insulation: up to 400MΩ at 50V and 100V• AC voltage measurement: 0 to 400V• Voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)• Resistance: 0 to 40kω• Capacity: 0 to 4000nf• Current: 0 to. . .
CA6533
FEATURES• Insulation: up to 20GΩ at 50V, 100V, 250V and 500V• Voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)• Resistance: 0 to 400kω• Giant, 4000-count display + bargraph (simultaneous reading of. . .
Machine Installation Testers
CA6121
FEATURESDielectric test: at 1000, 1250 and 1500V AC with:• Adjustment of max current threshold• Display of actual voltage and current• Test with or without timer function• Floating, voltage-free output for greater safety Insulation test:. . .
Multifunction - installation testers
CA6115
FEATURES• Insulation: 5kΩ to 600MΩ at 100, 250 or 500V DC• 1P earth: 0. 15Ω to 10kΩ by the 62% measurement method (1 auxiliary rod only)• Selective earth measurement by means of a clamp (available as a option)• Differentials:. . .
Multimeters
CA5011
FEATURES• Automatic AC/DC recognition• AC/DC voltage: 400mV to 1000V (5 cal. )• Utilisation frequency: 20Hz to 10kHz• Typical accuracy: 0. 5% - Impedance: 10MΩ• AC/DC intensity: 400µA to 10A (6 cal. )• Resistance: 400Ω to 40MΩ (6. . .
CA5205
FEATURES• AC/DC voltage: 200mV to 600V (5 cal. )• Typical accuracy 1% - Impedance: 3MΩ• Automatic AC/DC recognition• Resistance: 200Ω to 20MΩ (6 cal. )• Audible continuity test: R < 700Ω• 18mm-digit display for exceptional. . .
CA5210
The Adp input on this instrument enables it to be connected to an ammeter clamp and a whole range of probes FEATURES• AC/DC voltage: 400mV to 600V (5 cal. )• Typical accuracy: 1%. Impedance: 10MŮ (Velec low impedance of 270kŮ)• resistance: 400Ů to. . .
CA5220
FEATURES• AC/DC voltage: 400mv to 600V (5 cal. )• Bandwidth: 40Hz-500Hz except cal. 400mv (100Hz)• Typical. Accuracy. Of 1%+/-1ct for DC, 1. 5%+/-1ct for AC• AC/DC intensity 40ma to 10A (3 cal. )• Typ. Acc. Of 1. 5%+/-1pt for DC, 2%+/-2pt for. . .
CA5230
FEATURES• 40-segment bargraph• automatic or manual calibre selection• AC/DC voltage: 20mV-399. 9mV/0. 40V-3. 999V/4V-39. 99V/40V-399. 9V/400V-600V• typical accuracy: 0,25%. Impedance: 10MΩ• bandwidth: 40Hz-1000Hz• AC/DC intensity 40mA to 10A (3. . .
CA5240
FEATURES• 40000ct LCD display• 40-segment bargraph• AC/DC voltage: 400mV to 600V (5 cal. )• Bandwidth: 40Hz-1000Hz for intensity & 500Hz for V (except 400mV: 60Hz)• Peak factor: 3 • Typical accuracy: 0,1%. Impedance: 10MΩ• AC/DC intensity 40mA. . .
CA5260
FEATURES• Backlit, 4000-count display• AC/DC voltage: 400mV to 600V (5 cal. )• Input impedance: 10MΩ• Bandwidth: 40Hz-500Hz (except cal. 400mV, 100Hz)• 2 AC/DC current calibres: 400µA and 4000µA• Resistance: 400Ω to 40 MΩ (6. . .
Multimeters (Basic)
CDA103
• Voltage measurement up to 600V AC or DC, typ. accuracy 2%, at low impedance (max 600kΩ). • Automatic activation for U>600mV • Automatic stop for U<600mV • Automatic AC/DC recognition• Automatic calibre selection • Phase/neutral identification. . .
CDA104
• Automatic backlighting • HOLD, VOLTEST functions (indication of I voltage present in continuity)• 200mV AC/DC calibre as per user manual• Measurement of voltage up to 600V AC or DC (1mV-1999mV/2V-199. 9V/200V-600V), typ. accuracy 2%, at low impedance. . .
CDA30
• Phase detection without contact: 195 V AC < U < 265 V AC (1 diode)• Utilisation frequency: 45 - 400 Hz• Autotest of the 9 V battery• Electrical safety: IEC 1010-1 600V Cat II• Dimensions: 179 x 47 x 33mm. Weight: 120 gExamples of. . .
CDA40
• Voltage test: 12 to 690 V AC/DC (7 diodes)• Utilisation frequency: 0. . . 400 Hz• Polarity test: LED +/-• Voltage protection: 1000 V• Impedance: 400 kΩ• Autotest of 9 V battery• Touch prods positioned 19mm apart (2P+E current sockets)• Electrical. . .
CDA50
• Voltage test: 12 to90V AC/DC (7 LEDs) with indication by buzzer of voltage over 50V• Phase/neutral identification• Utilisation frequency: 0-400Hz• Polarity test: LED +/-• Voltage protection: 1000V• Autotest of the 9V battery and overall operation of. . .
CDA60
• Voltage test: 12 to 690V AC/DC (7 LEDs) with indication by buzzer of voltage over 50V• Touch prods positioned 19mm apart (2P+E current sockets)• Phase/neutral identification (using one hand only!)• Polarity test: LED +/-• Audible continuity test R. . .
Power, Energy & Harmonics Monitors / Analysers
CA8310
FEATURES• C. A Power View software for programming the instrument on a PC under Windows• Display: real-time analogue display, waveforms and simultaneous harmonics analysis, trend curves, full-screen zoom, etc. • IEC 1010 600V Cat III accessories,. . .
CA8334
Handy and very compact, this instrument also gives numerous calculated values and several processing functions in line with current standards: EN 50160, IEC 61000-4-15, IEC 61000-4-30, IEC 61000-4-7. FEATURES• Colour LCD screen for graphic. . .
CA8350
BASIC VERSION:FFT Analysis Functions • Oscilloscope Mode For Displaying Curves • Software (+ USB Cable) For Generating And Printing Data Reports• Comes With A Choice Of C-Type Ammeter Current Clamp Sensors (1000A), MN (6A), Ampflex Flexible. . .
F23
FEATURES• True RMS• Intensity: 1000A and 1500A peak• Voltage: 600V and 1500V peak• Power: 600kW, VA or var• Power factors and power shift• Measurement of total harmonic distortion• Large display with 3 reading levels (3x10000cts)• IEC 1010-2-032. . .
F25
FEATURES• Wide screen, with bargraph, 2x10000cts for displaying TRMS measurements, DC and AC, up to 600V and 1000A• Rank by rank measurement up to the 25th rank of all harmonics parameters as absolute values (A or V) or relative values. . .
F27
FEATURES• True RMS. • Intensity: 1000A and 1500A peak• Voltage: 600V and 1500V peak• Power: 600kW, VA or var. • Power factors and power shift. • Special measurements on transformers in the presence of harmonics. • Harmonics distortion parameters,. . .

Frequency / RPM

Stroboscopes
CDA9452
When the flashes of the CDA 9452, directed onto an object with periodic movement, are of the same frequency as that of the phenomenon under observation, the object appears immobile. The frequency expressed in flashes per minute can then be read off the. . .
Tachometers
CA25
• measures at a distance (by photorefletion) or by contact (with mechanical attachments)• rotation: up to 100 000 rpm• accuracy: 0. 01%• double 100,000-count digital or analogue display• movement (m/min) with calibrated wheel attachement• memory. . .
CA27
Measure at a distance (by photo refletion) or by contact (by mechanical attachments) rotation: up to 100 000 rpm. SPECIFICATIONS

Range - 100,000 rpmACCURACY: - 0. 01%DISPLAYdouble 100,000-count digital or analogue display. . .

Light

Light Meters
CA811
FEATURES INCLUDE• 3˝ digit display (2000counts)• measurement range: 20 to 20,000 lux • measurement by silicon photodiode• resolution: 0. 01 lux• functions: HOLD / Backlighting / lux or fc /Max • accuracy ±(3%Reading + 10counts)• I. E. C. spectral. . .
CA813
FEATURES INCLUDE• 3˝ digit display (2000counts)• measurement range: 20 to 200,000 lux • measurement by silicon photodiode• resolution: 0. 01 lux• functions: HOLD / Backlighting / lux or fc /Peak • accuracy ±(3%Reading + 10counts)• I. E. C. spectral. . .
Light Sensors
CA808
Under its housing, there is a Kodak-threaded insert enabling it to be mounted on a photo tripod. Its simple, captive elastomer cover protects the sensitive part of the sensor during storage or transport. The C. A 808 luxmeter cell is designed for. . .

Recording & Logging

Electrical measurement
CA601
Features• Digital current recorder: 0. 5 to 600A RMS (accuracy 2%R)• Best resolution automatically selected• Acquisition frequency automatically adjusted (4096 samples/hour max) according to real acquisition time, with no prior configuration (data. . .
L Series
All Loggers are supplied with Windows software for displaying and analyzing recorded data and printing graphs and result listings. The L series of loggers provide 3 function modes:• RECORD mode for the data acquisition and memorization phase• STAND-BY. . .

Temperature

Infrared Thermometer / Pyrometers
CA878 & CA880
All the functions can be operated with just a single hand. The trigger can be locked on to carry out temperature difference measurements (dT function) by sweeping across the target. The laser sight, available on model CA880, makes it extremely easy to. . .
Thermometers
CA861
• 1 K-type thermocouple input• measurement range: - 40°C to + 1350°C• accuracy ± (0. 1%R + 1°C)• 3˝ digit display (2000counts)• functions: MAX / HOLD / °C or °F / Backlighting• resolution: 0. 1°C or 1°C• shockproof protective sheath• dimensions: 173 x 60. 5. . .
CA863
• 2 K-type thermocouple inputs• differential (dT) temperature measurement• accuracy ±(0. 3%r + 1°C)• measurement range: -50°C to +1300°C• 3˝ digit display (2000counts)• functions: MAX / HOLD / °C or °F / Backlighting• resolution: 0. 1°C or 1°C• shockproof. . .
CA865
• 3˝ digit display (2000counts)• 1 input with Pt 100 sensor• functions: MAX / HOLD / °C or °F / Backlighting• measurement range: - 50°C to + 200°C• accuracy ± 0. 5°C• resolution: 0. 1°C• shockproof protective sheath• dimensions: 173 x 60. 5 x 38mm - weight:. . .

Temperature & Humidity

Temperature & Humidity Indicators
CDA846
FEATURES• 3˝ digit display (2000counts)• functions: MAX / HOLD / °C or °F / Backlighting• measurement range: -20°C to +60°C; -0 to 100%RH• temperature accuracy: ±0. 5°C from 0 to 60°C, ± 1°C from -20°C to 0°C• hygometric accuracy: ±2. 5%RH from 10. . .
Email this page

Do you know a colleague who will be interested in these products? Send them a link to this page.

 

 

 

 

Top of page

Home : Sales : Hire : Services : Calibration : Contact Us

Product Directory : Privacy policy : Copyright © 2009 BSRIA Instrument Solutions : Terms and Conditions : Logout :